🌐 Translate
Automatic translation is available via Google Translate: Open translated version.

Spectrum analyzer

Spectrum Sweep screen

Press F + 5 NOAA to turn on the Spectrum analyzer. The current VFO or memory frequency will be the center frequency of the spectrum sweep.

Spectrum Analyzer 1

Spectrum Analyzer 2

The spectrum analyzer can also be used with ScnRng mode.

[!NOTE] Navigation uses UP / DOWN on UV-K5, or LEFT / RIGHT on UV-K1. The active layout follows SetNav.

[!NOTE]

[!IMPORTANT] The spectrum analyzer does not behave identically across radio hardware. The V1 / V2 radios are built around the BK4819 receiver, while the V3 (K5v3) uses the BK4829. These are different receiver chips, with a different front-end, LNA/PGA gain stages, AGC behaviour and RSSI scaling.

As a result:

Trigger modes: AUTO vs MANUAL

Short-press M to toggle between AUTO and MANUAL trigger modes. The top-left indicator shows the active mode:

Long-press M to reset the spectrum analyzer to its default settings.

Saving settings on exit

When you leave the Spectrum Sweep screen with EXIT, the spectrum analyzer writes its persistent settings to flash. The next time you open the analyzer, these values are restored:

This persistence was expanded after v5.4.0: older builds saved only the scan step, bar count, and receiver bandwidth. In current builds, starting the spectrum analyzer from ScnRng mode no longer overwrites the saved scan step or bar-count preference; the active scan range still defines the sweep span.

The vertical scale (dbMax, 3 / 9 in MANUAL) is not persisted: it is reset to the default display window every time the analyzer is opened. The current sweep frequency/window, the UP / DOWN scrolling step, modulation type, backlight toggle, temporary blacklist, and detail-monitor register adjustments (LNAs, LNA, PGA) are also not saved by this EXIT action. If you are on the Detail Monitor screen, EXIT first returns to the sweep screen; press EXIT again from there to save and leave the analyzer.

Current builds also improve 8.33 kHz frequency rounding in bandscope / spectrum workflows, so displayed and tuned frequencies stay aligned more predictably on aviation-style steps.

Button functions

Key Function
1 / 7 Increase / decrease frequency step between bars
2 / 8 Increase / decrease the frequency step used when scrolling with UP / DOWN
3 / 9 In MANUAL: adjust dbMax (vertical scale) · In AUTO: cycle sensitivity profile (WEAK ↔ NORM ↔ STRG)
4 Toggle the number of bars (channels) in the graph
5 Frequency input for the lower sweep frequency (value in MHz, * = decimal point)
6 Toggle receiver bandwidth
0 Toggle modulation type (FM / AM / USB)
* / F Increase / decrease squelch trigger level in 1 dB steps — takes effect in MANUAL; in AUTO the auto-tracker overrides it on the next sweep
M short Toggle AUTO / MANUAL trigger mode
M long Reset spectrum analyzer to defaults
UP / DOWN on UV-K5, or LEFT / RIGHT on UV-K1 Shift the sweep window up / down in frequency · During RX: stop reception and resume the sweep in the chosen direction
Side button 1️⃣ Exclude the current frequency from the spectrum scan
Side button 2️⃣ Toggle backlight
PTT Switch to detail monitoring of the last received frequency
EXIT Save persistent spectrum settings, then return to the previous screen / function

[!TIP] The sweep alternates direction on each full cycle to reduce directional bias. The < / > indicator next to A:xxxx lets you see at a glance which half of the sweep is currently active.

[!NOTE] In MANUAL mode, the spectrum curve is drawn without cosmetic smoothing. This makes narrow peaks line up more closely with the raw RSSI used by the squelch detector.

Detail Monitor screen

LNA

Button functions

[!NOTE] LNAs / LNA / PGA are live diagnostic values, not saved settings. They are driven by the receiver’s AGC and are not persisted on exit. Their available steps and their meaning differ between the BK4819 (V1/V2) and the BK4829 (V3), so they cannot be compared value for value across platforms.